TransPRK Performed with 1050Hz Ultra-High-Speed Excimer Laser

zero_point
  • language_icon_ko
  • language_icon_ja
  • language_icon_mn
  • language_icon_zh
  • language_icon_ru
BookBook
First eye, Quick Consultation
첫눈이

Ask anything!

AMARIS 1050 RED

All cutting and correction completed with a single laser beam.
All-laser LASEK uses no blade, from epithelial removal to vision correction
100% laser-only non-contact vision correction.
German Schwind's Amaris Red equipment fires ultra-high-speed pulses with
7D Eye Tracker : 7-dimensional eye tracking system technology that tracks eye micro-movements in real-time.
This minimizes corneal thermal damage and creates smoother cutting surfaces.

Result: shorter surgery time, less pain, and clearer vision quality.

Fastest excimer laser

Speed and stability combined

AMARIS RED corrects 1 diopter in just 1.3 seconds
with 1050Hz ultra-fast pulse laser.
50% faster than existing equipment, preserving more corneal tissue
while minimizing thermal damage.

  • Standard laser
  • AMARIS RED
This scene is dramatized for understanding and may differ from reality.

Fastest excimer laser

Speed and stability combined

AMARIS RED corrects 1 diopter in just 1.3 seconds
with 1050Hz ultra-fast pulse laser.
50% faster than existing equipment, preserving more corneal tissue
while minimizing thermal damage.

  • Standard laser
  • AMARIS RED
This scene is dramatized for understanding and may differ from reality.

0.54mm Ultra-fine cutting

More precise than cells, smoother

Smaller laser beams enable precise surgery.
3.5x thinner 0.54mm precise beam
quickly and smoothly polishes the corneal surface for high-quality vision recovery.

More precise laser

Smallest beam size among excimer lasers for finer correction

  • 2.0mm

    Laser beam size

  • 0.68mm

    Laser beam size

  • 0.54mm

    Laser beam size

7D Eye tracking system

Technology that calculates all eye movements

7D ultra-precise eye tracker follows in real-time
to control laser targeting.
Even if the eye moves during surgery, position is corrected instantly for safe, accurate correction.

AI Heat dispersion system

Disperse heat, maintain eye stability

AI automatically analyzes laser energy
to maintain constant corneal temperature.
Prevents heat accumulation, minimizes cell damage
significantly reducing post-surgery pain and inflammation.
Maintains stability even at high speed.

  • Standard laser
  • AMARIS RED
This scene is dramatized for understanding and may differ from reality.

3D SmartPulse technology

Laser irradiation based on
cornea's 3D structure

Laser irradiation based on cornea's 3D structure
3D precise laser matching the eye's spherical shape.
Reduces corneal surface roughness for faster recovery
and clearer vision.
Improves surgery stability and target vision achievement rate.

  • Conventional method

    2D (flat) laser irradiation may roughen corneal surface.

  • NEW 'SPT' method

    Smoother corneal surface polishing for fast recovery and reduced light scatter

AMARIS RED LASEK vs Standard LASEK

Slide to see more

ItemAMARIS 1050RS REDOther laser equipment
Corneal surface
Laser beam size0.54mm (smallest Beam Size) Uniform
smooth cutting surface for maximum precision
0.68mm ~ 2.0mm Rough cutting edges, low precision
Laser beam typeSuper Gaussian - Flying Spot (only) 3D SmartPulse Technology→ Smooth cutting, minimal vision distortionBroad Slit Scanning / Flat Top - Flying Spot / Gaussian-Flying Spot→ Uneven energy distribution, cutting deviation possible
Laser cutting speed1050Hz (fastest cutting speed)
Under 1.3 sec per 1D correction, minimal thermal damage
20Hz ~ 500Hz Over 2 sec per 1D correction, longer surgery time
Beam size on cornea0.54mm (same as actual beam size)
100% energy delivery without loss
0.95mm+ Beam spread reduces energy efficiency
Time per diopter1.3 sec (fastest cutting speed)
Fast cutting for quick recovery and stable vision
Over 2 sec, thermal damage risk and delayed recovery
Eye tracking method7D eye tracking (X, Y, Z Rotation, Y Rotation, Static/Dynamic Cyclo Torsion, Time) Accurate recognition of micro-movementsUp to 6D tracking (X, Y, Static Cyclo Torsion) Limited precision
Eye tracking speed1050Hz (faster than laser cutting)
Latency-Free (0ms delay) instant response
1050Hz or less 3ms+ delay possible

Today LASEK
Faster and more comfortable

Advanced LASEK combining German Schwind's technology and Pain Control System, minimizing side effects like astigmatism, light scatter, and pain for recovery within 48 hours.

AMARIS RED equipment before 2023 with software-only upgrade
cannot connect to SIRIUS.

AMARIS RED x SIRIUS

Precision system seamlessly connecting
diagnosis to surgery

All equipment and data organically linked in one data flow for faster, more accurate vision correction.

Clearer without light scatter

Today LASEK offers fast recovery but may cause side effects like light scatter and myopia regression from optical zone reduction.
We minimize side effects and maximize vision quality with wide, precise low-stimulation correction linking AMARIS RED × SIRIUS × Pain Control System.

  • Standard LASEK with high thermal damage

  • Zero Pain LASEK with low thermal damage

Surgery designed for pain control,Pain Control System

Precisely calculates laser contact points
to minimize overlapping areas,
lowers corneal surface temperature through Frost Cooling to reduce damage and pain.

3D precision diagnosis reading
individual eye structure

German Schwind SIRIUS
(SIRIUS)

3D precision diagnosis reading individual eye structure
3D analysis of corneal curvature, thickness, and refraction,
simultaneous front and back imaging for 3D pre-surgery diagnosis.
Designs optimal correction results with precision data-based personalized vision maps.

Correction plan matching individual eye structure
Accurate diagnosis creates precise results.

3D Optical tomography

Reads the eye in 3D, including invisible areas

3D Corneal Topography technology
simultaneously scans front and back of cornea.
Precisely analyzes fine asymmetry, curvature, and distortion
in 3D data for error-free diagnosis.

SIRIUS corneal thickness map

3D Optical tomography

Reads the eye in 3D, including invisible areas

3D Corneal Topography technology
simultaneously scans front and back of cornea.
Precisely analyzes fine asymmetry, curvature, and distortion
in 3D data for error-free diagnosis.

SIRIUS corneal thickness map

Wavefront Aberration analysis

Analyzes light scatter causes numerically

Measures eye's total refraction error (high-order aberrations)
to accurately identify blur and light scatter causes.
This data is directly reflected in AMARIS RED surgery design
for clear, sharp vision recovery.

Wavefront aberration analysis

AI-based auto axis correction

AI controlling up to 0.1mm error

AI Alignment System
automatically detects and corrects fine deviation between visual and optical axes.
Maintains accurate center even with micro eye movements
to prevent alignment errors.

Real-time data matching

One data flow from diagnosis to surgery

3D data analyzed by SIRIUS
synchronizes in real-time with AMARIS RED laser system.
This linkage instantly generates
custom ablation profile optimized for individual eye structure.

Real-time data matching
From accurate diagnosis to precise correction

Understanding the eye,
designing vision precision process

  • 1 STEPPrecision 3D diagnosis
    (SIRIUS system)

    3D analysis of front/back corneal structure, thickness, curvature, asymmetry
    through optical tomography.

  • 2 STEPAI-based correction design

    AI analysis system automatically calculates
    corneal cutting depth, axis, and correction range.

  • 3 STEPUltra-precise laser correction (AMARIS RED)

    Uses German SCHWIND's AMARIS RED with 0.54mm
    ultra-fine beam and 1050Hz ultra-fast cutting.
    Frost Cooling lowers corneal surface temperature
    to reduce damage and pain.

  • 4 STEPPost-surgery precision check and recovery

    Immediate post-surgery SIRIUS examination
    confirms correction results and corneal stability.

Hospital trusted by doctors
Difference between specialists and experts
shown in results

Individual discomfort, blur, or halos may occur, requiring continuous follow-up and treatment.

profile
Why Choose First Eye

Doctors' Doctor,
Director Yun

Trusted clinic chosen by many

Trusted clinic chosen by many

Expert in complications, revision surgery

Expert in complications,
revision surgery

Premium system with advanced equipment

Premium system
with advanced equipment

Lifetime doctor system

Lifetime doctor
system

pointer-playpointer-pausepointer-swiper-horizonpointer-swiper-verticalpointer-swiper-handle